MSME Registered with valid UDHYAM certificate. Startup India registered under DPIIT.

Electrical Safety Audits for
Industrial & Commercial Facilities

Identify Electrical Risks. Improve
Safety. Strengthen Compliance.

Nexurja conducts systematic electrical safety assessments to identify potential hazards in electrical installations, evaluate protection and earthing systems, and provide practical recommendations for risk reduction and corrective action.
Electrical failures can contribute to industrial fires, equipment damage, unplanned downtime and regulatory concerns. Nexurja delivers rigorous, data-driven Electrical Safety Audits to help safeguard your workforce, protect high-value assets and identify areas requiring corrective action, with assessments undertaken with reference to the Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023, as amended, applicable standards and other relevant statutory requirements.

Banner Electrical Safety Audit Page

Our Electrical Safety Audit Scope

01 — Electrical Installation Assessment

Inspection of electrical equipment, panels, switchboards, cables, busbars, switchgear and associated installations for visible safety and condition-related concerns.

02 — Earthing & Grounding System

Assessment of earthing arrangements, earth continuity and relevant grounding parameters to identify potential safety risks.

03 — Protection System Review

Review of protective devices, circuit breakers, relays, fuses and protection settings against the electrical system configuration and operating requirements.

04 — Electrical Thermal Inspection

Thermal imaging of accessible electrical equipment to identify abnormal temperature rise, loose connections, overloaded components and other thermal anomalies.

05 — Cable & Connection Assessment

Inspection of accessible cable terminations, joints, connections and routing for potential deterioration, overheating or safety concerns.

06 — Lightning & Surge Protection

Assessment of lightning protection arrangements and surge protection devices, where applicable.

07 — Electrical Safety Practices

Review of electrical panels, access, identification, isolation arrangements, housekeeping and other relevant operational safety practices.

08 — Corrective Action & Risk Prioritisation

Identification and prioritisation of observations according to their potential safety and operational significance.

Thermal Imaging as Part of
Electrical Safety Assessment

Electrical connections and components can develop abnormal temperature patterns before a visible failure occurs. Where appropriate, Nexurja uses thermal imaging to identify temperature anomalies in electrical panels, switchgear, cable terminations, busbars, transformers and other accessible equipment.

Typical observations may include:

Loose Connections

Abnormal heating at terminals and joints.

Overloaded Components

Temperature patterns associated with excessive loading.

Phase Imbalance

Unusual temperature differences between phases.

High-Resistance Connections

Localised heating that may warrant further investigation.

Equipment Hotspots

Abnormal thermal patterns requiring inspection or corrective action.

Audit methodology

Pre-Audit Review

Review available electrical drawings, single-line diagrams, connected load, previous audit reports and relevant operational information.

Site Inspection

Systematic inspection of electrical installations and safety-critical components.

Measurements & Testing

Conduct appropriate electrical measurements and diagnostic tests based on the scope and site conditions.

Thermal Inspection

Thermal imaging of accessible electrical equipment where applicable.

Risk Assessment

Evaluate observations and identify potential safety, reliability and operational risks.

Recommendations

Develop practical corrective and preventive recommendations.

Audit Report

Provide a structured report containing observations, photographs/thermal images where applicable, risk prioritisation and recommended actions.

What the Client Receives

What You Receive

Electrical Safety Audit Report Including, as applicable:

  • Site observations
  • Electrical measurement results
  • Thermal images
  • Identified safety concerns
  • Earthing/grounding observations
  • Protection-system observations
  • Photographic evidence
  • Risk prioritisation
  • Recommended corrective actions
  • Suggested preventive measures

The Nexurja Approach

Engineering-Led
Assessment

Our audits combine site inspection, electrical measurements, thermal imaging and engineering analysis, where applicable.

Evidence-Based
Findings

Observations are supported by measurements, photographs, thermal images and other available evidence.

Risk-Based
Prioritisation

We help clients distinguish between observations requiring immediate attention and those that can be addressed through planned maintenance.

Actionable
Recommendations

The objective is not simply to identify deficiencies, but to provide practical corrective and preventive actions.

Who Should Consider an Electrical Safety Audit?

Who Can Benefit?
Manufacturing & Process Industries

For plants with significant electrical loads, motors, furnaces, transformers and process equipment.

Commercial Buildings

Office buildings, malls, hotels, hospitals and other large electrical installations.

Warehouses & Industrial Facilities

Facilities with extensive electrical distribution and material-handling systems.

Residential Societies

Large residential complexes with HT/LT distribution systems, DG systems and common-area electrical infrastructure.

Solar & Renewable Energy Facilities

Electrical systems associated with solar plants and associated balance-of-system equipment.