MSME Registered with valid UDHYAM certificate. Startup India registered under DPIIT.

Industrial Power Quality Analysis
Harmonics. Power Factor.
Voltage Disturbances. —
Diagnosed at the Source.

Nexurja assesses industrial electrical systems to identify harmonics, reactive-power issues, voltage disturbances and other power-quality problems that can affect equipment performance, system reliability and electricity costs.

Using power-quality measurements, event logging and engineering analysis, we help identify the nature and possible source of electrical disturbances and evaluate appropriate corrective measures.

Banner Power Quality Analysis Page

OUR APPROACH

Measure → Analyse → Diagnose → Mitigate

Measure

Capture voltage, current, power, power factor, harmonics and relevant electrical events under actual operating conditions.

Analyse

Examine trends, harmonic spectra, load behaviour and recorded events.

Diagnose

Correlate electrical abnormalities with major loads and operating conditions.

Mitigate

Evaluate appropriate corrective measures and their technical and financial implications.

What We Analyse

Harmonics

Voltage and current THD, individual harmonic orders and harmonic trends associated with non-linear loads.

Power Factor & Reactive Power

kW, kVAr, kVA, power factor, load variation and reactive-power behaviour.

Voltage Quality

Voltage imbalance, sags, swells, interruptions and other relevant voltage disturbances.

Electrical Events

Monitoring and analysis of disturbances that may affect sensitive equipment, automation and production processes.

Neutral & Triplen Harmonics

Assessment of neutral-current loading and relevant triplen harmonic components where required.

Typical Industrial
Loads Investigated

We correlate power-quality measurements with the operating behaviour of major loads to help identify potential sources and contributing factors.

Induction Furnaces | VFDs | UPS Systems | Welding Equipment | Large Motors | Power Electronic Converters | Capacitor Banks

From Diagnosis to Corrective Action

Depending on the findings, Nexurja can evaluate:

Power Factor Correction

Assessment of appropriate capacitor or dynamic compensation requirements.

Harmonic Mitigation

Evaluation of passive or active harmonic filtering solutions.

Detuned Capacitor Systems

Assessment of detuned reactor arrangements where harmonic interaction with capacitor banks is a concern.

Operational Improvements

Recommendations for load configuration or operating practices where appropriate.

What You Receive

A concise list:

  • Power-quality measurement data
  • Harmonic analysis
  • Load and power-factor analysis
  • Recorded electrical events
  • Engineering interpretation of findings
  • Identification of potential causes
  • Recommended corrective measures
  • Preliminary technical sizing where required
  • Financial assessment where applicable
  • Power Quality Study Report

Why Nexurja?

Instrumentation & Engineering Expertise

Power-quality assessment backed by electrical and instrumentation engineering experience.

Measurement-Based Diagnosis

Recommendations are based on recorded electrical behaviour rather than assumptions.

Solution-Oriented

We can take the study beyond diagnosis to evaluation of appropriate mitigation measures.

Independent Technical Perspective

Our focus is on identifying the problem and evaluating technically appropriate solutions.